Configuring LCD2021
Default configuration is J1 and J2 installed. This configures the RS-232 to 19 200 baud and I²C to slave address 0x5C -
depending on which connector is used. Please refer to the Appendix of this manual for programming notes.
RS-232 port: J0, J1, J2 - control baud rate
RS-232 format is 8N1 (8 characters, no parity, one stop bit)
I²C port: J0, J1, J2, J3 - sets slave peripheral address
Baud Rate
Slave Address
J3 J2 J1 J0
50H Off
Off
Off
Off
1200
52H Off
Off
Off
On
54H Off
Off
On
Off
2400
56H Off
Off
On
On
58H Off
On
Off
Off
9600
5AH Off
On
Off
On
5CH Off
On
On
Off
19200
5EH Off
On
On
On
60H On
Off
Off
Off
1200
62H On
Off
Off
On
64H On
Off
On
Off
2400
66H On
Off
On
On
68H On
On
Off
Off
9600
6AH On
On
Off
On
6CH On
On
On
Off
19200
6EH On
On
On
On