Command Syntax Default Notes
Read Version Number FE 36
254 54
254 ’6’
Reads the
firmware ver-
sion number
of the module.
Returns a 1-byte
value.
Enter flow control mode FE 3A [full] [empty]
254 58 [full] [empty]
254 ’:’ [full] [empty]
off Sets "full" and
"empty" marks
for the 80 byte
display buffer.
When buffer
reaches [full]
display will
return 0xFE to
host. When
buffer reaches
[empty] display
will return 0xFF.
Exit flow control mode FE 3B
254 59
254 ’;’
Turns off flow
control.
7 Appendix: Specifications and Options
7.1 Specifications
Table 20: Environmental Specifications
Standard Temperature Extended Temperature
Operating Temperature 0
C to +50
C -20
C to +70
C
Storage Temperature -20
C to +70
C -40
C to +85
C
Operating Relative Humidity 90% max non-condensing 90% max non-condensing
Table 21: Electrical Specifications
Supply Voltage 4.75 - 5.25 Vdc (optional 7 - 35 Vdc)
Supply Current 10 mA typical
Supply Backlight Current 115 mA typical
Matrix Orbital LCD4041 26